Inductive Conductivity Sensor LDL100

  • Reduce inaccuracies associated with a time-based cleaning process
  • Improve process performance with flexible measurement points
  • Compact, high-quality sensor design prevents failures and unplanned downtime
  • Simplify your installation and commissioning processes
  • Loss-free signal transmission of measurement values
Share on facebook
Share on twitter
Share on linkedin
Share on pinterest
Share on whatsapp
Share on email

Description

Inductive Conductivity Sensor

Product characteristics
Number of inputs and outputsNumber of analogue outputs: 1
Process connectionG 1/2 external thread
Application
Special featureGold-plated contacts
Mediaconductive liquids
Note on media
water
milk
CIP liquids
Cannot be used forSee the operating instructions, chapter “Function and features”.
Medium temperature [°C]-25…100; (< 1 h: 150)
Pressure rating [bar]16
Vacuum resistance [mbar]-1000
Electrical data
Operating voltage [V]18…30 DC
Current consumption [mA]< 60
Protection classIII
Reverse polarity protectionyes
Power-on delay time [s]2
Inputs / outputs
Number of inputs and outputsNumber of analogue outputs: 1
Outputs
Total number of outputs1
Output signalanalogue signal; IO-Link
Output functionanalogue output; scalable; selectable conductivity / temperature
Number of analogue outputs1
Analogue current output [mA]4…20
Max. load [Ω]500
Measuring/setting range
Measuring range [µS/cm]100…15000
Temperature measurement
Measuring range [°C]-25…150
Accuracy / deviations
Accuracy (in the measuring range)10 % MW ± 25 µS/cm
Conductivity measurement
Resolution [µS/cm]
1
Drift [%/K]0,2 %/K MW ± 25 µS/cm
Repeatability5 % MW ± 25 µS/cm
Long-term stability1 % MW ± 25 µS/cm
Temperature measurement
Accuracy [K]20…50 °C: < ± 0,5 K; -25…150 °C: < ± 1,5 K
Repeatability [K]0,2
Resolution [K]0.1
Response times
Conductivity measurement
Response time [s]< 2; (T09; Damping = 0)
Temperature measurement
Response time [s]< 9; (T09)
Interfaces
Communication interfaceIO-Link
Transmission typeCOM2 (38,4 kBaud)
IO-Link revision1.1
SDCI standardIEC 61131-9
IO-Link device ID0x000399 / 921
ProfilesMeasuring Sensor, Identification and Diagnosis
SIO modeno
Required master port typeA
Process data analogue1
Min. process cycle time [ms]5.6
Operating conditions
Ambient temperature [°C]-40…60
Storage temperature [°C]-40…85
ProtectionIP 68; IP 69K; (IP 68: 7 days / 3 m water depth / 0.3 bar)
Tests / approvals
EMC
DIN EN 61000-6-2
DIN EN 61000-6-3
Shock resistance
DIN EN 60068-2-2750 g (11 ms)
Vibration resistance
DIN EN 60068-2-620 g (10…2000 Hz)
MTTF [years]172
Mechanical data
Weight [g]270.5
Materialsstainless steel (1.4404 / 316L); PEEK; PEI; FKM
Materials (wetted parts)PEEK; stainless steel (1.4404 / 316L)
Process connectionG 1/2 external thread
Remarks
Remarks
MW = measured value
Pack quantity1 pcs.
Electrical connection
ConnectionConnector: 1 x M12 (EN 61067-2-101); Contacts: gold-plated

REQUEST A QUOTE!

Fast Shipping

Stocked Inventory

Competitive Pricing

High-Quality Products

Subscribe to our newsletter and recevie a $50 voucher!

Get updates and learn from the best

Inductive Conductivity Sensor LDL100 61f0351559fd9

Inductive Conductivity Sensor LDL100 61f0351559ffa