(08) 6161 6987

Inductive Conductivity Sensor LDL200

  • Reduce inaccuracies associated with a time-based cleaning process
  • Improve process performance with flexible measurement points
  • Compact, high-quality sensor design prevents failures and unplanned downtime
  • Simplify your installation and commissioning processes
  • Loss-free signal transmission of measurement values
Share on facebook
Share on twitter
Share on linkedin
Share on pinterest
Share on whatsapp
Share on email

Description

Inductive Conductivity Sensor

Product characteristics
Number of inputs and outputs Number of analogue outputs: 1
Process connection G 1 external thread Aseptoflex Vario
Application
Special feature Gold-plated contacts
Media conductive liquids
Note on media
water
milk
CIP liquids
Cannot be used for See the operating instructions, chapter “Function and features”.
Medium temperature [°C] -25…100; (< 1 h: 150)
Pressure rating [bar] 16
Vacuum resistance [mbar] -1000
Electrical data
Operating voltage [V] 18…30 DC
Current consumption [mA] < 100
Protection class III
Reverse polarity protection yes
Power-on delay time [s] 2
Inputs / outputs
Number of inputs and outputs Number of analogue outputs: 1
Outputs
Total number of outputs 1
Output signal analogue signal; IO-Link
Output function analogue output; scalable; selectable conductivity / temperature
Number of analogue outputs 1
Analogue current output [mA] 4…20
Max. load [Ω] 500
Measuring/setting range
Conductivity measurement
Measuring range [µS/cm] 100…1000000
Temperature measurement
Measuring range [°C] -25…150
Accuracy / deviations
Conductivity measurement
Accuracy (in the measuring range) 2 % MW ± 25 µS/cm
Resolution [µS/cm]
1 (0…10000)
10 (10000…100000)
100 (100000…1000000)
Drift [%/K] 0,1 %/K MW ± 25 µS/cm
Repeatability 1 % MW ± 25 µS/cm
Long-term stability 0,5 % MW ± 25 µS/cm
Temperature measurement
Accuracy [K] 20…50 °C: < ± 0,2 K; -25…150 °C: < ± 1,5 K
Repeatability [K] 0,2
Resolution [K] 0.1
Response times
Conductivity measurement
Response time [s] < 2; (T09; Damping = 0)
Temperature measurement
Response time [s] < 40; (T09)
Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9
IO-Link device ID 0x00039A / 922
Profiles Measuring Sensor, Identification and Diagnosis
SIO mode no
Required master port type A
Process data analogue 1
Min. process cycle time [ms] 5.6
Operating conditions
Ambient temperature [°C] -40…60
Storage temperature [°C] -40…85
Protection IP 68; IP 69K; (IP 68: 7 days / 3 m water depth / 0.3 bar)
Tests / approvals
EMC
DIN EN 61000-6-2
DIN EN 61000-6-3
Shock resistance
DIN EN 60068-2-27 50 g (11 ms)
Vibration resistance
DIN EN 60068-2-6 20 g (10…2000 Hz)
MTTF [years] 129
Mechanical data
Weight [g] 580.5
Materials stainless steel (1.4404 / 316L); PEEK; PEI; FKM
Materials (wetted parts) PEEK
Process connection G 1 external thread Aseptoflex Vario
Remarks
Remarks
MW = measured value
Pack quantity 1 pcs.
Electrical connection
Connection Connector: 1 x M12 (EN 61067-2-101); Contacts: gold-plated
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — LDL200-01 — 13.09.2019

REQUEST A QUOTE!

Related products

Fast Shipping

Stocked Inventory

Competitive Pricing

High-Quality Products

Subscribe to our newsletter and recevie a $50 voucher!

Get updates and learn from the best

Inductive Conductivity Sensor LDL200 6150192ce9aac

Inductive Conductivity Sensor LDL200 6150192ce9ac5