Magnetic-inductive volumetric flow meters

The magnetic-inductive volumetric flow sensors of the SM series monitor liquids. They detect the three process categories volumetric flow quantity, consumed quantity and medium temperature. They are frequently used in cooling circuits, e.g. in steelworks, the automotive industry and in glassmaking. In water management and industrial installations, the sensors are used for water consumption measurement.
Peak consumption, present consumption or accumulated consumption can be accessed and adjusted via programmed switch and alarm level settings – all at the touch of a button.
The units feature two switching outputs which can be programmed as normally open or normally closed. For output of the measured value, one switching output can also be configured as a scalable analogue output. For consumed quantity monitoring, the other output transmits counting pulses to the controller.
In addition to volumetric flow monitoring, the SM also monitors the temperature of the medium. It is displayed on the unit and provided for signal processing. The sensor is thus particularly suited for monitoring cooling circuits.
The robust stainless steel housing and high protection rating provide high security even in harsh environments.
Depending on the volumetric flow quantity to be detected, devices with different process connections are offered.

 

  • With volumetric flow quantity, total quantity and temperature indication
  • High accuracy, repeatability and measurement dynamics
  • For use in conductive media from 20 μS/cm
  • With switching output, analogue output and pulse output
  • Clearly visible LED display

 

Share on facebook
Share on twitter
Share on linkedin
Share on pinterest
Share on whatsapp
Share on email

Description

Magnetic-inductive volumetric flow meters

ProductMeasuring rangeMaterials (wetted parts)Electrical designProcess connectionOutput function
SM60000.1…25 l/min
0.005…1.5 m³/h
stainless steel (1.4404 / 316L); PEEK; FKMPNP/NPNG 1/2 DN15normally open / normally closed; (parameterisable); analogue
SM80000.2…100 l/min
0.01…6 m³/h
stainless steel (1.4404 / 316L); PEEK; FKMPNP/NPNG 1 DN25normally open / normally closed; (parameterisable); analogue
SM60040.1…25 l/min
0.03…6.6 gpm
stainless steel (1.4404 / 316L); PEEK; FKMG 1/2 DN15analogue
SM70000.2…50 l/min
0.01…3 m³/h
stainless steel (1.4404 / 316L); PEEK; FKMPNP/NPNG 3/4 DN20normally open / normally closed; (parameterisable); analogue
SM90005…300 l/min
0.3…18 m³/h
stainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); PEEK; Centellen; FKMPNP/NPNG 2 DN50normally open / normally closed; (parameterisable); analogue
SM61000.1…25 l/min
0.005…1.5 m³/h
stainless steel (1.4404 / 316L); PEEK; EPDMPNP/NPNG 1/2 DN15normally open / normally closed; (parameterisable); analogue
SM20005…600 l/min
0.3…36 m³/h
stainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); PEEK; Centellen; FKMPNP/NPNG 2 DN50normally open / normally closed; (parameterisable); analogue
SM80040.2…100 l/min
0.1…26.4 gpm
stainless steel (1.4404 / 316L); PEEK; FKMG 1 DN25analogue
SM81000.2…100 l/min
0.01…6 m³/h
stainless steel (1.4404 / 316L); PEEK; EPDMPNP/NPNG 1 DN25normally open / normally closed; (parameterisable); analogue
SM90045…300 l/min
0.3…18 m³/h
80…4755 gph
1.3…79.3 gpm
stainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); PEEK; Centellen; FKMG 2 DN50analogue
SM200180…9600 gph
1.3…160 gpm
stainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); PEEK; Centellen; FKMPNP/NPNG 2 DN50normally open / normally closed; (parameterisable); analogue
SM900180…4800 gph
1.3…80 gpm
stainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); PEEK; Centellen; FKMPNP/NPNG 2 DN50normally open / normally closed; (parameterisable); analogue
SM70040.2…50 l/min
0.02…13.22 gpm
stainless steel (1.4404 / 316L); PEEK; FKMG 3/4 DN20analogue
SM20045…600 l/min
0.3…36 m³/h
80…9510 gph
1.3…158.5 gpm
stainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); PEEK; NBR reinforced fibre; FKMG 2 DN50analogue
SM91005…300 l/min
0.3…18 m³/h
stainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); PEEK; Centellen; EPDMPNP/NPNG 2 DN50normally open / normally closed; (parameterisable); analogue
SM80016…1584 gph
0.1…26.4 gpm
stainless steel (1.4404 / 316L); PEEK; FKMPNP/NPNG 1 DN25normally open / normally closed; (parameterisable); analogue
SM60011.5…396 gph
0.03…6.6 gpm
stainless steel (1.4404 / 316L); PEEK; FKMPNP/NPNG 1/2 DN15normally open / normally closed; (parameterisable); analogue
SM40005…3000 ml/minstainless steel (1.4404 / 316L); PEEK; FKMPNP/NPNG 1/4 DN6normally open / normally closed; (parameterisable); analogue
SM05105…900 l/min
0.3…54 m³/h
stainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); PEEK; Centellen; FKMPNP/NPNG 2 DN50normally open / normally closed; (parameterisable); analogue
SM21005…600 l/min
0.3…36 m³/h
stainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); PEEK; Centellen; EPDMPNP/NPNG 2 DN50normally open / normally closed; (parameterisable); analogue
SM71000.2…50 l/min
0.01…3 m³/h
stainless steel (1.4404 / 316L); PEEK; EPDMPNP/NPNG 3/4 DN20normally open / normally closed; (parameterisable); analogue
SM66040.1…25 l/min
0.03…6.6 gpm
stainless steel (1.4404 / 316L); PEEK; FKM1/2 NPT DN15analogue
SM260180…9600 gph
1.3…160 gpm
stainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); PEEK; FKMPNP/NPN2 NPT DN50normally open / normally closed; (parameterisable); analogue
SM86016…1584 gph
0.1…26.4 gpm
stainless steel (1.4404 / 316L); PEEK; FKMPNP/NPN1 NPT DN25normally open / normally closed; (parameterisable); analogue